Data Dictionary
>
FPSADMIN Tables
> FPSADMIN.DASH_P_OPERATIONS
Table FPSADMIN.DASH_P_OPERATIONS"
See comments in DASH_REF_P_OPERATIONS view.
-
Schema: FPSADMIN
-
Tablespace: FPSDATA
-
Primary key: FACILITY, OPERATION
|
Column |
Type |
Nullable |
Comment |
|---|---|---|---|
|
FACILITY |
VARCHAR2(6) |
N |
Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* from FPSINPUT.GEN_FACILITIES) |
|
OPERATION |
VARCHAR2(50) |
N |
Operation is usually the primary level of routing in the MES and the level where the facility typically reports moves. FPS only allows one tool per step so our step is a lower level of routing than operation although both may be the same if the MES only allows one tool per operation. Note that because operation can include multiple steps and therefore multiple process families that we cannot have any association to equipment by operation. (* from FPSINPUT.RTG_OPERATIONS) |
|
MODULE |
VARCHAR2(12) |
Modules are departments of people who manage certain areas of the fab. The modules are assigned ownership of a set of tools to operate and maintain as well as steps on the route that they are responsible for executing. Since many of our tables include tool and step information together, we must distinguish between the owner of the step (WIP_MODULE), the owner of the operation of the tool (EQP_MODULE), and the owner of the maintenance of the tool (MNT_MODULE). WIP_MODULE is used to credit moves and set goals. Each route-step is assigned to a process family and then its wip_module is defined by the process family. EQP_MODULE is used to group tools particularly for tool performance reporting. Similar to WIP, each tool is dynamically assigned to a process family based on its assignments and then its eqp_module is defined by the process family. MNT_MODULE is usually the same as EQP_MODULE but unlike EQP_MODULE is not dependent on assignments but only on the EQP hierarchy. Each tool is assigned to an eqp_type and each eqp_type is assigned to a mnt_family and each mnt_family is assigned to a mnt_module. (* from FPSINPUT.GEN_MODULES) |
|
|
NUM_PROCESSES |
NUMBER(4) |
||
|
NUM_PROCESSES_ACTIVE |
NUMBER(4) |
||
|
OPERATION_DISPLAY |
VARCHAR2(50) |
N |
All xxx_display columns are used in place of the column xxx for display purposes. The values of these columns can be changed at any time without having to worry about other tables referencing it. (* from FPSINPUT.RTG_OPERATIONS) |
|
OPERATION_FAMILY |
VARCHAR2(36) |
Grouping of route-step that is completely dependent on routing information from MES. The primary use of this field is for filtering on Operations Dashboard. Unfortunately for our database structure and naming convention, this field no longer has any link to operation. This is because operation is used primarily for Oper Moves and it is normal for steps in an operation to belong to multiple MES routing groups. For example, a sink step and a furnace step and a measurement step are in the same operation but each step belongs to the appropriate sink/furnace/measurement MES routing groups which we store in operation family. Since Dashboard already uses both operation and operation_family extensively and independently, we decided not to rename either column but simply remove the link. Please note that operation family is similar to process family and in fact they are often the same. The key differences are that operation family has nothing to do with equipment and that comes straight from ETL with no complex logic. Process family is the link between routing and equipment for the Operations Dashboard and therefore has complex logic. (* from FPSINPUT.RTG_OPERATION_FAMILIES) |