data-dictionary

FPSAPP.FDC_WAFER_HIST

Data Dictionary

>

FPSAPP Tables

> FPSAPP.FDC_WAFER_HIST

Table FPSAPP.FDC_WAFER_HIST"

Stores history of FDC wafer-based events. Most likely this table will be referenced by WIP_APD_WAFER_HIST to include in WIP_WAFER_HIST.

  • Schema: FPSAPP

  • Tablespace: FPSDATAHIST

  • Primary key: EVENT_TIME, LOT, WAFER, EVENT


Column

Type

Nullable

Comment

EVENT_TIME

TIMESTAMP(6)

N

We expect FDC applications to provide a timestamp field which we write to this column via either FPSAPP procedure or ETL. When we then import this data into the ETL via WIP_APD_xxx_HIST views, we will use this timestamp to populate the inst field without the fractional seconds and we will use the fractional seconds as opt_sort_within_sec. (* from FPSINPUT.FDC_LOT_HIST)

LOT

VARCHAR2(32)

N

A lot is a group of units that process together. Usually lot_id or lot_number in MES. All units in a lot are in the same carrier but there may be multiple lots in a carrier. (* from FPSINPUT.WIP_LOTS_STATIC)

WAFER

VARCHAR2(32)

N

Field that uniquely identifies a wafer. (* from FPSINPUT.WIP_WAFER_HIST)

EVENT

VARCHAR2(48)

N

This is the event registered in the MES. This is for the historical record and display only. Each event is mapped to an FPS event_type and the event_type is what is used by FPS applications. (* from FPSINPUT.WIP_EVENTS)

EVENT_COMMENT

VARCHAR2(512)

Comment associated with the event. (* from FPSINPUT.WIP_HOLD_FUTURE)

FACILITY

VARCHAR2(6)

N

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* from FPSINPUT.GEN_FACILITIES)

LOGGED_ENTITY

VARCHAR2(36)

Entity to which event is logged in the MES. This could be a main tool, subtool, entity, or port. In MNT tables this could be a vehicle or durable as well which is why the column width is wider. If main tool or port, we apply the event to all entities. If subtool we apply to all within the subtool. If entity we apply only to the entity. (* from FPSINPUT.EQP_EVENT_HIST)