Data Dictionary
>
FPSADMIN Tables
> FPSADMIN.WIP_WAFER_ERROR_HIST
Table FPSADMIN.WIP_WAFER_ERROR_HIST"
When ADM_LOAD_EVENT_HIST_VIA_APD fails to insert any record into WIP_WAFER_HIST, it writes the original values from WIP_APD_WAFER_HIST into this table so that we can debug the failure. This also allows us the option to insert the record manually into WIP_WAFER_HIST later if desired. Please note that this table must have the same columns in the same order as WIP_WAFER_HIST. This table has the same PK as WIP_WAFER_HIST so that the columns will be listed in the same order in the GrimRepo snapshot used by DWH_build but the PK is permanently disabled because we never want the insert to fail.
-
Schema: FPSADMIN
-
Tablespace: FPSDATAHIST
-
Primary key: INST, LOT, WAFER, LOT_SEQ_WITHIN_SEC
|
Column |
Type |
Nullable |
Comment |
|---|---|---|---|
|
INST |
DATE |
N |
Time when the event occurred. (* from FPSINPUT.WIP_EVENT_HIST) |
|
LOT |
VARCHAR2(32) |
N |
A lot is a group of units that process together. Usually lot_id or lot_number in MES. All units in a lot are in the same carrier but there may be multiple lots in a carrier. (* from FPSINPUT.WIP_LOTS_STATIC) |
|
WAFER |
VARCHAR2(32) |
N |
Field that uniquely identifies a wafer. (* from FPSINPUT.WIP_WAFER_HIST) |
|
LOT_SEQ_WITHIN_SEC |
NUMBER(2) |
N |
For rows with identical timestamps, sequence records to get proper sequence (* from FPSINPUT.WIP_EVENT_HIST) |
|
ACTUAL_DURABLE_USED |
VARCHAR2(129) |
Actual durable used as logged by the tool during processing of the lot. This can be a comma delimited string if multiple durables are used. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
ACTUAL_MACHINE_RECIPE |
VARCHAR2(100) |
Machine recipe used to process the lot as logged during processing by the tool. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
ETP_BEG_ACTION |
VARCHAR2(24) |
This is the action passed to the UPDATE_ETP_STATUS_BEG procedure and is useful for debugging ETP to see what action this event triggered. (* from FPSINPUT.WIP_WAFER_HIST) |
|
|
EVENT |
VARCHAR2(48) |
This is the event registered in the MES. This is for the historical record and display only. Each event is mapped to an FPS event_type and the event_type is what is used by FPS applications. (* from FPSINPUT.WIP_EVENTS) |
|
|
EVENT_COMMENT |
VARCHAR2(512) |
Comment associated with the event. (* from FPSINPUT.WIP_HOLD_FUTURE) |
|
|
EVENT_INST1 |
DATE |
User-defined field which can store any instant relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_INST2 |
DATE |
User-defined field which can store any instant relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_INST3 |
DATE |
User-defined field which can store any instant relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_PARM1 |
VARCHAR2(128) |
User-defined parameter which can store any value relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_PARM2 |
VARCHAR2(128) |
User-defined parameter which can store any value relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_PARM3 |
VARCHAR2(128) |
User-defined parameter which can store any value relevant to the event. Description of use should be noted in WIP_EVENTS table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
EVENT_TYPE |
VARCHAR2(12) |
Event Type (* from FPSINPUT.EQP_SCHED_EVENTS_MANUAL) |
|
|
FACILITY |
VARCHAR2(6) |
Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* from FPSINPUT.GEN_FACILITIES) |
|
|
INSERTED_TIME |
TIMESTAMP(6) |
N |
Timestamp field set by trigger storing SYSTIMESTAMP when record was inserted in the table. (* from FPSINPUT.WIP_EVENT_HIST) |
|
JOB_ID |
VARCHAR2(64) |
Automatically set by trigger when the first lot of a job logs an event to the tool. (* from FPSBASE.WIP_LOT_HIST) |
|
|
LOGGED_ENTITY |
VARCHAR2(36) |
Entity to which event is logged in the MES. This could be a main tool, subtool, entity, or port. In MNT tables this could be a vehicle or durable as well which is why the column width is wider. If main tool or port, we apply the event to all entities. If subtool we apply to all within the subtool. If entity we apply only to the entity. (* from FPSINPUT.EQP_EVENT_HIST) |
|
|
OPERATOR |
VARCHAR2(64) |
In history tables, this is the username of the person or system who logged the event. In EQP_MNT_FUTURE, this is the username of the person who input the information about the maintenance event. Usernames can be looked up in GEN_USERS to get full names, email address, etc. Please note that the existence of each username in GEN_USERS is optional, meaning that it is never required for the username logged in the operator column to be in GEN_USERS. (* from FPSINPUT.WIP_EVENT_HIST) |
|
|
OPT_SORT_WITHIN_SEC |
NUMBER(21,6) |
This number is the order of the event within the same second for the same lot (WEH) or wafer (WWH) or entity (EEH). If the event is logged with a sequence number then this value should be that sequence number (and it is fine if this is an overall sequence number even though it only matters compared to other events in the same second). Otherwise if the event time includes milliseconds then this can be the milliseconds. Otherwise just choose the best sort order. This value does not need to be 1, 2, 3, etc. (* from FPSINPUT.WIP_EVENT_HIST) |