data-dictionary

FPSAPP.CTR_P_H_VALID_FINISHED_PF_BANK

Data Dictionary

>

FPSAPP Views

> FPSAPP.WIP_WAFER_HIST_LOOP

View FPSAPP.CTR_P_H_VALID_FINISHED_PF_BANK

This view filters only valid lots and gets some information for the prd and facility. It is used both as a base for other CTR views that provide the chart data as well as individual for the drilldown to guarantee that the drilldown matches the charts. This view is quite similar to CTR_P_H_VALID_FINISHED_LOTS and any changes should likely be made to both.

Column

Comment

FACILITY

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* inherited from FPSINPUT.GEN_FACILITIES)

LOT

A lot is a group of units that process together. Usually lot_id or lot_number in MES. All units in a lot are in the same carrier but there may be multiple lots in a carrier. (* inherited from FPSINPUT.WIP_LOTS_STATIC)

QTY

Quantity of units in the lot according the qty_unit defined for the facility. It is required for all lots in each facility to have their qty defined in the same units therefore the change in the unit is critical to defining the facility. For example, a pretest facility might have a sort step in the middle where we learn the qty of die. Prior to this step we know only the wafer qty but after this step we know both wafer and die. Since wafer is the only qty we know throughput the flow then wafer must be defined as the qty unit for this facility. Die can then be populated as sec_qty when it is known. Similarly the wafer saw facility might have a step in the middle where we cut the wafers into die. After this step we no longer know the number of wafers which means that die must be the qty unit for this facility and wafers can be the sec_qty prior to the saw step. Please note that a lot with qty of 0 is allowed but only if the sec_qty is greater than 0. This is unusual but one case is where we know the wafers will be scrapped but cannot be scrapped quite yet. (* inherited from FPSINPUT.WIP_EVENT_HIST)

FINISHED_INST

LOT_GROUP

Lot_group is a grouping of lot_family and is the highest grouping in the lot type hierarchy. There should be only a few values for lot_group, i.e. Prod, Dev, TW. We group WIP and moves by lot_group on the dashboard and we group cycle time calculations by lot_group so this is an important field. (* inherited from FPSINPUT.WIP_LOT_GROUPS)

NUM_STEPS_COMP

BANK

Lots which are not on a route are considered in a bank and the bank name indicates why the lot is off route. Bank must be NA for lots which are on a route. Our standard filter for active lots is bank = NA. (* inherited from FPSINPUT.RTG_BANKS)

PROCESS_FAMILY

See https://help.inficonims.com/display/DW/Guide+to+Process+Families. (* inherited from FPSINPUT.RTG_PROCESS_FAMILIES)

MODULE

Modules are departments of people who manage certain areas of the fab. The modules are assigned ownership of a set of tools to operate and maintain as well as steps on the route that they are responsible for executing. Since many of our tables include tool and step information together, we must distinguish between the owner of the step (WIP_MODULE), the owner of the operation of the tool (EQP_MODULE), and the owner of the maintenance of the tool (MNT_MODULE). WIP_MODULE is used to credit moves and set goals. Each route-step is assigned to a process family and then its wip_module is defined by the process family. EQP_MODULE is used to group tools particularly for tool performance reporting. Similar to WIP, each tool is dynamically assigned to a process family based on its assignments and then its eqp_module is defined by the process family. MNT_MODULE is usually the same as EQP_MODULE but unlike EQP_MODULE is not dependent on assignments but only on the EQP hierarchy. Each tool is assigned to an eqp_type and each eqp_type is assigned to a mnt_family and each mnt_family is assigned to a mnt_module. (* inherited from FPSINPUT.GEN_MODULES)

MODULE_DISPLAY

The name of the module displayed on all dashboards and reports. We allow a longer more descriptive name here although often this will be the same as the module. (* inherited from FPSINPUT.GEN_MODULES)

MODULE_BG_COLOR

PRD

Prd determines the route which is used to process the lot in the facility and what tools, recipes, durables, etc. can be used at each step. Prd also determines the next facility for the lot when it finishes its route. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* inherited from FPSINPUT.RTG_PRDS)

PLANPRD

Planning product used for all planning purposes. All lots with the same planprd are interchangeable to ship to the customer regardless of their prd, route, technology, wafer size, etc. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* inherited from FPSINPUT.RTG_PLANPRDS)

ROUTE

Route that has threading requirements (* inherited from FPSINPUT.RTG_STEP_THREADING)

WAFER_SIZE

If the facility only has one wafer size then this column should be null in both RTG_PRDS and EQP_TYPES. If the facility has more than one wafer size then a value of null in EQP_TYPES means that those tools can run all wafer sizes. See column IS_ANY_WAFER_SIZE for details. (* inherited from FPSINPUT.GEN_WAFER_SIZES)

WAFER_SIZE_DISPLAY

The name of the wafer_size displayed on all dashboards and reports. We allow a longer more descriptive name here although often this will be the same as the wafer_size. (* inherited from FPSINPUT.GEN_WAFER_SIZES)

ROUTE_FAMILY

Route_family indicates that all routes within the family have similar or even identical steps and have the same segments. At facilities where various prds share the same route it is likely that the route will be the route_family. This is sometimes referred to as the main process flow. It is used on Segment Summary and Line Viewer to group similar routes. (* inherited from FPSINPUT.RTG_ROUTE_FAMILIES)

ROUTE_GROUP

Route_group is the parent of route_family. Route_group is used on the Dashboard and other applications as a large grouping for filtering. At many sites this is referred to as technology. (* inherited from FPSINPUT.RTG_ROUTE_GROUPS)

STEP_TOTAL_SEC

STEP_BLOCK_SEC

STEP_HOLD_SEC

STEP_WAIT_SEC

STEP_DISP_SEC

STEP_PROC_SEC

STEP_ENDED_SEC

STEP_DOWN_SEC

STEP_SHUTD_SEC

FINISHED_PERIOD

PERIOD_SORT_ORDER

This column is only to sort the periods in the FLCT application. Normally this will match the period_start_inst but when sites has multiple period types like months and years then it is nice to be able to control the sort order. (* inherited from FPSINPUT.WIP_CTM_FORECAST)

PERIOD_TYPE

START_PERIOD

END_PERIOD

OVERALL_START_INST

QTY_UNIT

Defines the unit used to measure number of quantity. The key here is that this quantity must be known throughout the entire route through the facility. For example in a sort facility where lots enter in wafers and are broken into die but the number of wafers is still known when the lot completes the facility then the qty_unit must be wafer. It cannot be die because die is not known when the lot enters so die will be the sec_qty_unit. Similarly at a final test facility where the lots enter with both wafers and die known but only die are known when the lot completes the facility then the qty_unit must be die. It cannot be wafer because wafer is not known when the lot completes so wafer will be the sec_qty_unit. Please note the entire process from only wafers to only die must be split into at least two facilities because of this requirement. (* inherited from FPSINPUT.GEN_FACILITIES)

QTY_UNIT_PLURAL

Plural form of the quantity unit. For example if qty_unit is defined as wafer then the plural form would be wafers. (* inherited from FPSINPUT.GEN_FACILITIES)

PROCFAM_OR_BANK

MODULE_OR_BANK

MODULE_OR_BANK_DISPLAY

MODULE_OR_BANK_BG_COLOR