data-dictionary

FPSADMIN.DASH_P_WIP_EVENT_HIST

Data Dictionary

>

FPSADMIN Views

> FPSADMIN.WIP_WAFER_HIST_LOOP

View FPSAPP.DASH_P_WIP_EVENT_HIST

Basic query to WIP_LOT_HIST for display on lot page and Excel export.

Column

Comment

LOT

A lot is a group of units that process together. Usually lot_id or lot_number in MES. All units in a lot are in the same carrier but there may be multiple lots in a carrier. (* inherited from FPSINPUT.WIP_LOTS_STATIC)

INST

Time when the event occurred. (* inherited from FPSINPUT.WIP_EVENT_HIST)

LOT_SEQ_WITHIN_SEC

For rows with identical timestamps, sequence records to get proper sequence (* inherited from FPSINPUT.WIP_EVENT_HIST)

EVENT

This is the event registered in the MES. This is for the historical record and display only. Each event is mapped to an FPS event_type and the event_type is what is used by FPS applications. (* inherited from FPSINPUT.WIP_EVENTS)

EVENT_TYPE

Event Type (* inherited from FPSINPUT.EQP_SCHED_EVENTS_MANUAL)

STEP

A single processing step within a route representing a single tool visit. Step is often a very complex string and should rarely be displayed. Instead we should use process_display. (* inherited from FPSINPUT.RTG_ROUTE_STEPS)

ROUTE

Route that has threading requirements (* inherited from FPSINPUT.RTG_STEP_THREADING)

PROCESS

Process defines what occurs at a step. Different steps can share the same process if they are identical. Process should normally determine allowed tools and recipe although it can be overridden by step, route, prd, lot, and experiment for exceptions. Each process is dynamically assigned to one or more eqp_type-process_family combinations with use_pct. One process_family is determined to be primary. If grouping is done correctly, a process should only be one eqp_group with no crossover. (* inherited from FPSINPUT.RTG_PROCESSES)

PROCESS_DISPLAY

The name of the process displayed on all dashboards and reports. We allow a longer more descriptive name here although often this will be the same as the process. (* inherited from FPSINPUT.RTG_PROCESSES)

PRD

Prd determines the route which is used to process the lot in the facility and what tools, recipes, durables, etc. can be used at each step. Prd also determines the next facility for the lot when it finishes its route. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* inherited from FPSINPUT.RTG_PRDS)

BANK

Lots which are not on a route are considered in a bank and the bank name indicates why the lot is off route. Bank must be NA for lots which are on a route. Our standard filter for active lots is bank = NA. (* inherited from FPSINPUT.RTG_BANKS)

FACILITY

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* inherited from FPSINPUT.GEN_FACILITIES)

QTY

Quantity of units in the lot according the qty_unit defined for the facility. It is required for all lots in each facility to have their qty defined in the same units therefore the change in the unit is critical to defining the facility. For example, a pretest facility might have a sort step in the middle where we learn the qty of die. Prior to this step we know only the wafer qty but after this step we know both wafer and die. Since wafer is the only qty we know throughput the flow then wafer must be defined as the qty unit for this facility. Die can then be populated as sec_qty when it is known. Similarly the wafer saw facility might have a step in the middle where we cut the wafers into die. After this step we no longer know the number of wafers which means that die must be the qty unit for this facility and wafers can be the sec_qty prior to the saw step. Please note that a lot with qty of 0 is allowed but only if the sec_qty is greater than 0. This is unusual but one case is where we know the wafers will be scrapped but cannot be scrapped quite yet. (* inherited from FPSINPUT.WIP_EVENT_HIST)

QTY_DELTA

Difference in number of wafers due to an event that changes lot quantity (* inherited from FPSINPUT.WIP_EVENT_HIST)

TOOL

Tool is generally just the main tool. The exception is when different entities on the tool run completely independently and it is physically impossible to run wafers of the same lot across multiple entities. In this exception case, we may want to assign the entities to different eqp_types and therefore we should define each entity as a tool. Please note that when we do this there is no indication whatsoever that these different entities are on the same tool. (* inherited from FPSINPUT.EQP_TOOLS)

LOGGED_ENTITY

Entity to which event is logged in the MES. This could be a main tool, subtool, entity, or port. In MNT tables this could be a vehicle or durable as well which is why the column width is wider. If main tool or port, we apply the event to all entities. If subtool we apply to all within the subtool. If entity we apply only to the entity. (* inherited from FPSINPUT.EQP_EVENT_HIST)

ACTUAL_MACHINE_RECIPE

Machine recipe used to process the lot as logged during processing by the tool. (* inherited from FPSINPUT.WIP_EVENT_HIST)

NEXT_STEP

Event moved the lot to this new step (* inherited from FPSINPUT.WIP_EVENT_HIST)

NEXT_ROUTE

Event moved the lot to this new route (* inherited from FPSINPUT.WIP_EVENT_HIST)

OPERATOR

In history tables, this is the username of the person or system who logged the event. In EQP_MNT_FUTURE, this is the username of the person who input the information about the maintenance event. Usernames can be looked up in GEN_USERS to get full names, email address, etc. Please note that the existence of each username in GEN_USERS is optional, meaning that it is never required for the username logged in the operator column to be in GEN_USERS. (* inherited from FPSINPUT.WIP_EVENT_HIST)

EVENT_COMMENT

Comment associated with the event. (* inherited from FPSINPUT.WIP_HOLD_FUTURE)