data-dictionary

FPSAPP.CM_B_PROD_STARTS

Data Dictionary

>

FPSAPP Tables

> FPSAPP.CM_B_PROD_STARTS

Table FPSAPP.CM_B_PROD_STARTS"

See comments in CM_REF_B_PROD_STARTS view.

  • Schema: FPSAPP

  • Tablespace: FPSDATA

  • Primary key: FACILITY, PRD, ROUTE, LOT_TYPE, START_INST


Column

Type

Nullable

Comment

FACILITY

VARCHAR2(6)

N

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* from FPSINPUT.GEN_FACILITIES)

PRD

VARCHAR2(64)

N

Prd determines the route which is used to process the lot in the facility and what tools, recipes, durables, etc. can be used at each step. Prd also determines the next facility for the lot when it finishes its route. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* from FPSINPUT.RTG_PRDS)

ROUTE

VARCHAR2(256)

N

Route that has threading requirements (* from FPSINPUT.RTG_STEP_THREADING)

LOT_TYPE

VARCHAR2(24)

N

Lot_type is the base of the hierarchy that determines lot_family then lot_group. Ideally lot_type will come straight from the MES with little modification. (* from FPSINPUT.WIP_LOT_TYPES)

START_INST

DATE

N

Time when the lot started. (* from FPSINPUT.WIP_STARTS)

FIRST_STEP

VARCHAR2(256)

QTY

NUMBER

Quantity of units in the lot according the qty_unit defined for the facility. It is required for all lots in each facility to have their qty defined in the same units therefore the change in the unit is critical to defining the facility. For example, a pretest facility might have a sort step in the middle where we learn the qty of die. Prior to this step we know only the wafer qty but after this step we know both wafer and die. Since wafer is the only qty we know throughput the flow then wafer must be defined as the qty unit for this facility. Die can then be populated as sec_qty when it is known. Similarly the wafer saw facility might have a step in the middle where we cut the wafers into die. After this step we no longer know the number of wafers which means that die must be the qty unit for this facility and wafers can be the sec_qty prior to the saw step. Please note that a lot with qty of 0 is allowed but only if the sec_qty is greater than 0. This is unusual but one case is where we know the wafers will be scrapped but cannot be scrapped quite yet. (* from FPSINPUT.WIP_EVENT_HIST)

ROUTE_FAMILY

VARCHAR2(36)

Route_family indicates that all routes within the family have similar or even identical steps and have the same segments. At facilities where various prds share the same route it is likely that the route will be the route_family. This is sometimes referred to as the main process flow. It is used on Segment Summary and Line Viewer to group similar routes. (* from FPSINPUT.RTG_ROUTE_FAMILIES)

ROUTE_GROUP

VARCHAR2(36)

Route_group is the parent of route_family. Route_group is used on the Dashboard and other applications as a large grouping for filtering. At many sites this is referred to as technology. (* from FPSINPUT.RTG_ROUTE_GROUPS)

SCENARIO

VARCHAR2(16)

STEP_SEC_LONG_WAVG_TO_EOL

NUMBER(11)