Data Dictionary
>
FPSBASE Views
> FPSBASE.WIP_WAFER_HIST_LOOP
View FPSAPP.SCH_P_DISPATCH_CARRIERS
the carrier dispatch list
|
Column |
Comment |
|---|---|
|
FACILITY |
Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* inherited from FPSINPUT.GEN_FACILITIES) |
|
SCHED_GROUP |
This is the grouping of tools and processes which the FPS Scheduler schedules together. Since this is a parent of tool via tool->process_group and a parent of process via process->process_group, by definition each tool and each process can only be in one sched group. We need all related tools and processes to be in the same sched group for efficient scheduling. One example is sinks and furnaces because of queue times and batching. Another example is for smaller facilities like Assembly or Test where we might schedule the entire facility together. (* inherited from FPSINPUT.RTG_PROCESS_GROUPS) |
|
SCHED_TOOL |
the tool from the first lot that scheduled (* inherited from FPSAPP.SCH_W_SCHED_DURABLE_INSPECT) |
|
SCHED_CARRIER |
|
|
CARRIER_CURR_STATION |
|
|
SCHED_DURABLE |
|
|
CURR_CARRIER |
|
|
SLOT_NUM |
The slot number the durable is occupying in its pod. This applies when a durable is stored in a pod that can hold multiple durables. (* inherited from FPSINPUT.RTG_DURABLES) |
|
DURABLE_CURR_STATION |
|
|
LOT |
A lot is a group of units that process together. Usually lot_id or lot_number in MES. All units in a lot are in the same carrier but there may be multiple lots in a carrier. (* inherited from FPSINPUT.WIP_LOTS_STATIC) |
|
NUM_STEPS_AWAY |
Number of steps away not including steps which we know will be skipped nor those which we estimate will be skipped at least x pct of the time. This x value is configurable in GEN_FACILITIES using the smp_pct_for_num_steps_away column. (* inherited from FPSBASE.WIP_STEP_FUTURE) |
|
SCHED_START |
The first start time for the durable to be used (* inherited from FPSBASE.RTG_DURABLE_FUTURE_SCHED) |
|
SCHED_END |
|
|
IS_HIGHLIGHTED_PRTY |
This flag indicates if this priority should be highlighted on the dashboard. When we sort all priorities by priority_sort all Y should be first followed by all N. (* inherited from FPSINPUT.WIP_PRIORITIES) |
|
CURR_PRIORITY_DISPLAY |