List of all process links that are created through the MSOUI and grouped by the process link group.

  • Schema: FPSINPUT

  • Tablespace: FPSDATA

  • Primary key: FACILITY, PROCESS_LINK_GROUP, FROM_MSO_PROCESS_NA, TO_MSO_PROCESS_NA

  • Foreign keys: MSO_PROC_L_FK_PROC_LINK_GROUP: FACILITY, PROCESS_LINK_GROUP REFERENCES FPSBASE.MSO_PROCESS_LINK_GROUPS (FACILITY, PROCESS_LINK_GROUP)


Column

Type

Nullable

Comment

FACILITY

VARCHAR2(6)

N

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* from FPSINPUT.GEN_FACILITIES)

PROCESS_LINK_GROUP

VARCHAR2(64)

N

Process link group to that will allow the UI to tie links to rule. This value can be entered more than once to specify multiple to/from combinations.

FROM_MSO_PROCESS_NA

VARCHAR2(100)

N

Main processing step for the rule link. This is the step where the decision to tag lots is made and the skip/tag counter is incremented.

TO_MSO_PROCESS_NA

VARCHAR2(100)

N

Step that will be skipped or measured based on the lots that are tagged to measure or skip. Additionally lots completing this step will clear the counter for the corresponding sample rule.

DECISION_ON_SINGLE_FROM

CHAR(1)

TAG_PARM_NAME

VARCHAR2(50)

Name of the parameter to be set in the MES. This is sent to the on track-in of the FROM_MSO_PROCESS defined, or TO_MSO_PROCESS if the from is set to NA.

TAG_PARM_VALUE

VARCHAR2(50)

Value of the parameter to be set in the MES. This is sent to the on track-in of the FROM_MSO_PROCESS defined, or TO_MSO_PROCESS if the from is set to NA.

UPDATED_INST