Data Dictionary
>
FPSBASE Views
> FPSBASE.WIP_WAFER_HIST_LOOP
View FPSAPP.CTR_P_PRDS
This view creates a list of products and related information needed for the Cycle Time Report
|
Column |
Comment |
|---|---|
|
FACILITY |
Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* inherited from FPSINPUT.GEN_FACILITIES) |
|
FACILITY_DISPLAY |
The name of the facility displayed on all dashboards and reports. Facility is a short field since it is used in every join so we allow a longer more descriptive name here although often this will be the same as the facility. (* inherited from FPSINPUT.GEN_FACILITIES) |
|
FACILITY_SORT_ORDER |
|
|
FACILITY_COLOR |
|
|
QTY_UNIT |
Defines the unit used to measure number of quantity. The key here is that this quantity must be known throughout the entire route through the facility. For example in a sort facility where lots enter in wafers and are broken into die but the number of wafers is still known when the lot completes the facility then the qty_unit must be wafer. It cannot be die because die is not known when the lot enters so die will be the sec_qty_unit. Similarly at a final test facility where the lots enter with both wafers and die known but only die are known when the lot completes the facility then the qty_unit must be die. It cannot be wafer because wafer is not known when the lot completes so wafer will be the sec_qty_unit. Please note the entire process from only wafers to only die must be split into at least two facilities because of this requirement. (* inherited from FPSINPUT.GEN_FACILITIES) |
|
QTY_UNIT_PLURAL |
Plural form of the quantity unit. For example if qty_unit is defined as wafer then the plural form would be wafers. (* inherited from FPSINPUT.GEN_FACILITIES) |
|
PRD |
Prd determines the route which is used to process the lot in the facility and what tools, recipes, durables, etc. can be used at each step. Prd also determines the next facility for the lot when it finishes its route. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* inherited from FPSINPUT.RTG_PRDS) |
|
PLANPRD |
Planning product used for all planning purposes. All lots with the same planprd are interchangeable to ship to the customer regardless of their prd, route, technology, wafer size, etc. For detailed information on prd vs. planprd see table comments in RTG_PLANPRDS. (* inherited from FPSINPUT.RTG_PLANPRDS) |
|
ROUTE |
Route that has threading requirements (* inherited from FPSINPUT.RTG_STEP_THREADING) |
|
ROUTE_FAMILY |
Route_family indicates that all routes within the family have similar or even identical steps and have the same segments. At facilities where various prds share the same route it is likely that the route will be the route_family. This is sometimes referred to as the main process flow. It is used on Segment Summary and Line Viewer to group similar routes. (* inherited from FPSINPUT.RTG_ROUTE_FAMILIES) |
|
ROUTE_GROUP |
Route_group is the parent of route_family. Route_group is used on the Dashboard and other applications as a large grouping for filtering. At many sites this is referred to as technology. (* inherited from FPSINPUT.RTG_ROUTE_GROUPS) |
|
WAFER_SIZE |
If the facility only has one wafer size then this column should be null in both RTG_PRDS and EQP_TYPES. If the facility has more than one wafer size then a value of null in EQP_TYPES means that those tools can run all wafer sizes. See column IS_ANY_WAFER_SIZE for details. (* inherited from FPSINPUT.GEN_WAFER_SIZES) |
|
WAFER_SIZE_DISPLAY |
The name of the wafer_size displayed on all dashboards and reports. We allow a longer more descriptive name here although often this will be the same as the wafer_size. (* inherited from FPSINPUT.GEN_WAFER_SIZES) |
|
OVR_PROC_CT_DAYS_FOR_FLCT_XF |
Some sites prefer to use a fixed number for the processing time of each prd in the denominator of their X-Factor calculation. The FLCT app will use this value if populated in the X-Factor calculation instead of the calculation processing time. For sites which combine prd in the same facility to report a sequence of prds in FLCT, this value must be populated for the last prd in the same sequence but it should have the value of the total processing time for all prds in the sequence. (* inherited from FPSINPUT.RTG_PRDS) |
|
TARGET_CT_DAYS |
Number of days of cycle time targeted for the prd or bank. This target is only published internally which often means it is not even published to corporate planning. This should be less than or equal to the commit. (* inherited from FPSINPUT.RTG_BANKS) |
|
COMMIT_CT_DAYS |
Number of days of cycle time committed to the customer for the prd or bank. This commit is published externally. This should be greater than or equal to the target. (* inherited from FPSINPUT.RTG_BANKS) |