data-dictionary

FPSBASE.MSOUI_P_TAG_CONDITIONS

Data Dictionary

>

FPSBASE Views

> FPSBASE.WIP_WAFER_HIST_LOOP

View FPSAPP.MSOUI_P_TAG_CONDITIONS

This view provides tag conditions to the MSO UI.

Column

Comment

TAG_CONDITION_ID

Unique tag condition identification number. (* inherited from FPSBASE.MSO_TAG_CONDITIONS)

FACILITY

Facility is included in almost every join in the DWH so this represents a definitive split. A route must have all steps on tools in the same facility. A tool must process all lots in the same facility. If your site has multiple buildings where lots run on routes using tools in multiple buildings then everything should be one facility. For example, multiple Fab buildings. But if your site has independent facilities like Fab and Test and Assembly where lot may progress from one to the next but on different routes then these should be different facilities. Since this column is in virtually every table it is critical that the value here is exactly matches what is in the MES if the MES has facility. Use facility_display for the display friendly name displayed in applications. See site_name comment for client/site/facility example. (* inherited from FPSINPUT.GEN_FACILITIES)

IS_ACTIVE

Flag to enable or disable the tag condition. (* inherited from FPSBASE.MSO_TAG_CONDITIONS)

EXPIRY_DEACTIVATE_INST

Date column that automatically sets the tag condition to inactive once the date is past. (* inherited from FPSBASE.MSO_TAG_CONDITIONS)

TAG_CONDITION_NAME

Unique name identifying the external tag condition. (* inherited from FPSINPUT.MSO_EXTL_TAG_CONDITIONS)

TAG_CONDITION_TYPE

Define if the tag condition is either "ALLOWED", "ALWAYS", or "NEVER". ALLOWED: If all the conditions defined for the associated rule and lot at the FROM_MSO_PROCESS are true, then the lot can be tagged to measure at the TO_MSO_PROCESS. ALWAYS: If all the conditions defined for the associated rule and lot at the FROM_MSO_PROCESS are true, then the lot will ALWAYS be tagged to measure at the TO_MSO_PROCESS. NEVER: If all the conditions defined for the associated rule and lot at the FROM_MSO_PROCESS are true, then the lot can NEVER be tagged to measure at the TO_MSO_PROCESS. In all cases the counter value will still increment. (* inherited from FPSINPUT.MSO_EXTL_TAG_CONDITIONS)

UPDATED_INST

Time when the record was updated according to the source data. Note this is not the time when the record was actually updated in this table - it will almost always be earlier. (* inherited from FPSINPUT.GEN_FACILITIES)